Cole Hersee R2-400112-RN 40A 12V Form 2 Relay with resistor suppression

Special Price $8.91 Regular Price $9.99
In stock
SKU
R2-400112-RN
Cole Hersee R2-400112-RN 40A 12V Form 2 Relay with resistor suppression is available to buy in increments of 1

Cole Hersee R2-400112-RN 40A 12V Form 2 Relay, resistor suppression

Cole Hersee R2-400112-RN 40A 12V Form 2 Relay, resistor suppression

General purpose relays fit many vehicles. Typical applications include: lighting, starting, horn, heating and cooling. Standard ISO terminal footprint for Form A (SPST), Form C changeover (SPDT) and Form 2A (SPST, 2 terminals). Relays are available sealed and unsealed (unsealed are supplied with snap-in brackets.)

5 pin, 40 Amp, 12V Relay SPST

Specifications:

Ignition protected to SAE J1171 Pull-in voltage: 7.8V maximum at 12V DC, 15.6V at 24V DC.

Release voltage: 1.2V minimum at 12V DC, 2.4V at 24V DC.

Temperature range: -40°C to 85°C.

Operational life: Electrical to 100,000 cycles; Mechanical to 10 million cycles.

Contact Material: Silver alloy. dielectric strength: 500V rms between coil and contact.

Insulation resistance: 100MΩ minimum (500V DC).

Vibration resistance: 10-40Hz double amplitude 1.5mm.

Ignition protected to SAE J1171, Section 5.

Cole Hersee Relays are rated based on a steady state resistive load.

De-rate according to the type of load:

Motor load: inrush can be 5 to 10 x steady state current.

solenoid load: Inrush can be 10 to 20 x steady state current.

Incandescent lamp load: Inrush can be 10 to 15 x steady state current.